EC-C1200-450
- The EC-C1200 inverter should be mounted by using at least 6 pcs of M8 screws of suitable length.
- Installation must be done to a solid bracket or plate, so that the inverter frame is not experiencing any external twisting or bending force. The inverter should not be used as a structural support for other devices or parts of the system.
- Mounting direction and orientation can be selected freely.
EC-MG1200
- The EC-MG1200 multiconverter must be mounted by the T-slots on the sides and/or M8 threads in the ends of the cooling plate of the unit. The unit must be mounted using at least 8 different mounting points evenly distributed around the device.
- The top cover and enclosures on the bottom of the unit should not carry any weight or be tensioned against the mounting structures; only the mounting plate in the middle of the device should be used for supporting the weight of the device.
- Installation must be done to a solid bracket or frame, so that the converter's frame is not experiencing any external twisting or bending force. The inverter should not be used as a structural support for other devices or parts of the system.
- Mounting direction and orientation can be selected freely.
1) M8 threads
2) T-slot suitable for M8 nuts or bolts. If M8 nuts are used in the slot, care must be taken to make sure that the screws which are inserted into the nuts are not bottoming out against the cooling plate.