All connections for 24 V auxiliary power, PT100 temperature measurement, CAN bus and resolver wiring as well as the user configurable I/O connections of the EC-C1200 inverter are located in the X1 connector.
X1 connector of the EC-C1200 inverter (highlighted in red)
Pinout of the X1 connector for the EC-C1200. Detailed explanation of the connections are shown in table below.
Pin number | Signal name | Description |
1 | VIN_P | Positive Power Supply (7-33V) |
2 | POWER_ON | Active High, Turn ON @ >7.4V, Turn OFF @ < 5.8V |
3 | #STOP_2 | Active Low, STOP @ < 1.2V, RUN @ > 4.65V Pulling one #STOP down stops the inverter |
4 | RES_EXC_N | Resolver exitation, use twisted pair and shield |
5 | RES_EXC_P | Resolver exitation, use twisted pair and shield |
6 | PT_2 | PT100 or PT1000 temperature sensor input Connect sensor against signal GND |
7 | VP5V_OUT | +5V/200mA output for external sensors. Software control |
8 | CANH_A | CAN bus A, isolated (Functional isolation <100 VDC) |
9 | CANL_A | CAN bus A, isolated (Functional isolation <100 VDC) |
10 | USER_IO_5 | Digital input ('1' @ 3V, '0' @ 2V) (max. 10 mA) Digital output ('1' = 4.8V, '0' = 0V) (max. 10 mA) Digital output open collector (max. 80mA) |
11 | USER_IO_3 | Digital input ('1' @ 3V, '0' @ 2V) (max. 10 mA) Digital output ('1' = 4.8V, '0' = 0V) (max. 10 mA) Digital output open collector (max. 80 mA) Analog input (0-32V) (input impedance ~100 kOhm) |
12 | USER_IO_1 | Digital input ('1' @ 3V, '0' @ 2V) (max. 10 mA) Digital output ('1' = 4.8V, '0' = 0V) (max. 10 mA) Digital output open collector (max. 80 mA) Analog input (0-32V) (input impedance ~100 kOhm) |
13 | VIN_N | Negative Power Supply (0V) |
14 | SYNC_A | SYNC_A for Master/Slave |
15 | GND | Signal GND / PT100 or PT1000 GND |
16 | RES_SIN_N | Resolver input, use twisted pair and shield |
17 | GND | Signal GND / PT100 or PT1000 GND |
18 | PT_1 | PT100 or PT1000 temperature sensor input Connect sensor against signal GND |
19 | LOOP | High Voltage Diagnostic Loop |
20 | GND_CAN_A | GND for CAN bus A |
21 | GND_CAN_B | GND for CAN bus B |
22 | GND_IO | GND for IO, IO is isolated (Functional isolation <100 VDC) |
23 | USER_IO_2 | Digital input ('1' @ 3V, '0' @ 2V) (max. 10 mA) Digital output ('1' = 4.8V, '0' = 0V) (max. 10 mA) Digital output open collector (max. 80 mA) Analog input (0-32V) (input impedance ~100 kOhm) |
24 | #STOP_1 | Active Low, STOP @ < 1.2V, RUN @ > 4.65V Pulling one #STOP down stops the inverter |
25 | SYNC_B | SYNC_B for Master/Slave |
26 | RES_COS_N | Resolver input, use twisted pair and shield |
27 | RES_COS_P | Resolver input, use twisted pair and shield |
28 | RES_SIN_P | Resolver input, use twisted pair and shield |
29 | PT_3 | PT100 or PT1000 temperature sensor input Connect sensor against signal GND |
30 | GND | Signal GND / PT100 or PT1000 GND |
31 | LOOP | High Voltage Diagnostic Loop |
32 | CAN_H_B | CAN bus B, isolated (Functional isolation <100 VDC) |
33 | CAN_L_B | CAN bus B, isolated (Functional isolation <100 VDC) |
34 | USER_IO_4 | Digital input ('1' @ 3V, '0' @ 2V) (max. 10 mA) Digital output ('1' = 4.8V, '0' = 0V) (max. 10 mA) Digital output open collector (max. 80 mA) Analog input (0-32V) (input impedance ~100 kOhm) |
35 | GND_ENCLOSURE | Enclosure ground |